Note: Items marked with * are available to satisfy virtually
any users' applications.
Model |
Supply
Voltage* |
Output |
Freq.
Response |
No. of
Divisions * |
Output
Code |
Characteristics |
AE |
DC 5V
|
Open Collector
|
20000 count/s |
Gray code
(Related binary code) |
256 div.
512 div.
1024 div.
2048 div.
4096 div.
8192 div.
|
- Low cost, 8192 divisions.
- Outer dia. 67 mm, shaft 10 mm.
- Drip-proof construction.
|
AE
Angle
Detector
|
DC 5V
DC 15V |
Open Collector
|
20000 count/s |
720
1000
|
Excess reflected binary code
(special gray code) |
- Outer dia. 67 mm, shaft 10 mm.
- Drip-proof construction.
- Cam angles be easily obtained by combining with our programmable
cam switch SQ-12.
|
AEA
|
DC 5V
|
Open Collector
|
20000 count/s |
10000
(1000 div. x 10 turns) |
BCD
(Binary-coded decimal code) |
- Outer dia. 80 mm, shaft 10 mm.
- Drip-proof construction.
- Stroken can be easily controlled by combining with our programmable
cam switch SQ-13.
|
DC 15V
|
8192
(1024 div. x 8 turns) |
Gray code
(Related binary code) |
AT |
DC 24V
|
Open Collector
|
20000 count/s |
2 - 120 div.
|
BCD code
Binary code
(Pure binary code)
With TP(Strobe) |
- No. of div. and output code can be customized according to
customers' requirement
- Outer dia. 67 mm, shaft 10 mm.
- Drip-proof construction.
|
ATA |
DC 24V
|
Open Collector
|
20000 count/s |
2 - 32 div.
|
BCD code
Binary code
(Pure binary code)
With TP(Strobe) |
- No. of div. and output code can be customized according to
customers' requirement
- Outer dia. 55 mm, shaft 10 mm.
- Drip-proof construction.
|
AEC |
DC 5V
|
Line
driver
|
6000 count/s |
2048 div. x 8192 turns
|
BCD code
Serial transmission |
- Outer dia. 67 mm, shaft 10 mm.
- Counts up to 8191 turns, because of battery backup.
- Transits absolute signals and check flags serially.
- Incorporates incremental and index signals.
- Use of the hollow shaft eliminates the need of coupling.
|
AEF |
DC 5V
|
Line
driver
|
5000 count/s |
2048 div. x 8192 turns
|
BCD code
Serial transmission |
- Outer dia. 35 mm, shaft 6 mm.
- Counts up to 8191 turns, because of battery backup.
- Transits absolute signals and check flags serially.
- Incorporates incremental and index signals.
- Use of the hollow shaft eliminates the need of coupling.
|
AEH |
DC 5V
|
Line
driver
|
6000 count/s |
2048 div. x 8192 turns
|
BCD code
Serial transmission |
- Outer dia. 40 mm, shaft 6 mm.
- Counts up to 8191 turns, because of battery backup.
- Transits absolute signals and check flags serially.
- Incorporates incremental and index signals.
|